Hurricane Milton, Oct 10, 2024
70,394Marion County electric customers out, 31.3% at the Florida PSC 9 AM report
Or call (352) 780-1430. A licensed installer who serves your area calls back, usually within one business day.

What the lights on your generator are telling you
Free in-home estimate, written price, no obligation.
Get my estimateMost home standby generators talk to you through a few colored lights and a short message on the controller. Learning to read them takes two minutes and can save a wasted call.
On current Generac home standby units, Generac's support pages describe the lights this way:
- Green: ready. Utility power is present and the unit is in AUTO. Flashing green means it is running and carrying the house.
- Yellow: a non-critical alert, such as maintenance due or a warning. The generator should still run, but the alert needs attention soon.
- Red: the generator is OFF, or a fault has shut it down. Generac says service from a dealer may be required.
- Blue: the controller is in service mode.
Generac's code list ties most red codes, such as overcrank, overspeed, underspeed and overload, to the same advice: contact a dealer. A low battery code is the one the owner can often help with.
Kohler's RDC2 controller, used on many Kohler home units, spells faults out in words. A few you may see:
- Not in Auto: the unit will ignore the transfer switch until you press AUTO.
- Battery Voltage Low: the starting battery has sat below 12.5 volts. Kohler says to charge or replace it.
- Over Crank: three failed starting attempts. Kohler lists the fuel supply, spark plug and battery as the first things to check.
- Oil Press Low: a shutdown on low oil pressure. Kohler notes this switch does not protect against a low oil level, so the level still needs checking.
Write down the exact code or message before you clear anything. It is the most useful thing you can give a technician.
Safe checks to make before you call
A surprising number of no-start calls come down to something simple. These checks are all things the manufacturers themselves point owners to, and none of them involve opening the engine compartment.
- Is it in AUTO? Generac's troubleshooting starts with this question, and Kohler's controller shows a "Not in Auto" warning. A unit left in OFF or MANUAL after a test will not start on its own.
- Is the fuel valve on? Generac's outage guide says to confirm the fuel shutoff valve is ON and that there is enough fuel. On propane, look at the tank gauge. Generac notes that air in the lines after a refill can keep a unit from starting.
- Is the generator's breaker on? If the unit runs but the house stays dark, Generac says to confirm the main line circuit breaker on the generator is ON. Kohler says a breaker that trips again and again needs a dealer.
- How old is the battery? Generac puts typical battery life at 3 to 5 years and says the unit needs at least 12 volts to start. For a low battery code, it suggests leaving the unit in AUTO for a full 24 hour charge cycle.
- What does the oil look like? For a low oil pressure code, Generac says to check the level and call a dealer if it is correct. Do not overfill.
Stop there. Kohler's manual warns that a standby unit can start by itself, and that the battery must be disconnected and the engine cooled before anyone works on it. Leave that work to a technician.
If a code comes back after you clear it, Generac says the unit needs dealer service. That is the point to make the call.
Still under warranty? Start with the brand's dealer
Before paying anyone for a repair, find your warranty paperwork. If the generator is still covered, the brand usually wants the work done through its own dealer network, and work done elsewhere may not be paid for.
- Generac: most home standby models carry a 5 year limited warranty. Years one and two cover parts, labor and limited travel, year three covers parts, and years four and five cover engine and alternator parts. Generac says claims go through its independent servicing dealers, the unit must be registered, and proof of scheduled maintenance is required. Starting batteries are not covered.
- Kohler (now Rehlko): Kohler Energy took the Rehlko name in September 2024. Kohler's operation manual recommends that only its factory dealers install and service the generator.
- Champion: the home standby warranty runs 10 years or 2,000 hours, with labor and parts in the first two years. Champion says repairs must go through its home standby service dealers, and lists 1-877-338-0999 for warranty service.
- Briggs & Stratton: the company lists a standby generator support line, 800-732-2989, and a dealer locator on its website.
- Cummins: check the warranty booklet that came with the unit and contact a Cummins dealer for covered work.
If the warranty has run out, or the brand's dealer cannot get to you, that is where a request through this site helps. One request matches you with a licensed local technician who services generators. Ask up front which brands they work on, and tell them if any part of the unit is still under warranty. The brands comparison lists each warranty side by side.
After Hurricane Irma, 35,000 Ocala Electric customers and about 90% of Duke Energy's Marion County customers lost power, the kind of week a standby generator has to start on the first try.
What a repair visit involves and what it costs
A typical service call follows a simple pattern. The technician reads the controller's history, checks the battery, fuel supply and oil, looks over the wiring and the transfer switch, and runs the unit to see the fault happen. Then you get an explanation and a price for the fix before the work starts.
Published cost guides give a sense of scale. These are national figures, not a quote:
- Yelp's cost guide (2026): repairs on permanent whole-house units typically run $150 to $600, with about $200 for a common repair. It lists generator technicians at $60 to $75 an hour.
- Parts in the same guide: a battery $30 to $70, a voltage regulator $50 to $400, a transfer switch $500 to $1,500, and a stator $600 to $2,500, before labor.
- smallengine.directory (2026): a $75 to $150 trip charge for on-site diagnosis, $150 to $300 for a controller diagnostic and reset, and $400 to $1,500 to repair or replace a transfer switch. It notes that brand dealers often charge more than independent shops.
Many visits land at the small end: a battery, a clogged air filter, a tripped breaker or a fuel issue. Large numbers usually mean a major part such as a stator, a controller board or the transfer switch.
To keep the visit short and the bill clear, have the brand, model and serial number ready, along with the code on the screen and your maintenance records. Ask whether the trip charge is credited toward the repair, and ask for the price in writing before any part is ordered.
Call the utility, the gas company or the technician?
When the lights go out, it is not always the generator's problem, and some problems are not safe to wait on. Sort it out in this order.
- A downed or sagging power line: stay away and keep others away. SECO Energy's safety page says to assume any line is energized and to report it right away. If anyone is in danger, call 911. Then report it to your electric utility: Duke Energy Florida, SECO Energy, Ocala Electric Utility or Clay Electric, whichever serves your address. SECO's number is (352) 793-3801.
- You smell gas: leave the house first and do not look for the leak. TECO Peoples Gas says to leave the area, call 911, then call its 24 hour line at 877-832-6747. On propane, leave and call 911, then your propane supplier. Do not run or reset the generator.
- The whole street is dark: that is a utility outage. Report it to your utility. If the generator is in AUTO, it should start on its own.
- The street has power and you do not: check your main breaker, then call your utility before assuming the generator is at fault.
- The generator will not start, shows a red light, or will not shut off after power returns: that is a job for a generator technician.
Generac's outage guide also covers a unit that keeps running after utility power comes back. Its advice is to turn the generator's breaker off, let it cool, check for a code, and contact a dealer if it keeps running. When in doubt, do not touch anything electrical. Call and describe what you see.
Book repairs before storm season, not during it
NOAA's Atlantic hurricane season runs from June 1 through November 30, with the peak in August, September and October. That calendar shapes the generator business in Marion and Sumter County. After a named storm, everyone whose unit failed calls at once, and the wait for technicians and parts gets long.
Hurricane Irma showed how wide an outage can get here. A congressional office report from the storm listed 35,000 Ocala Electric customers without power, about 90% of Duke Energy's Marion County customers, 92% of Clay Electric's customers and 52% of SECO's Marion County customers. A generator that sat with a yellow light all summer is the one that fails that week.
The cheapest repair is the one found early:
- Listen for the weekly exercise. Kohler says exercising the unit weekly or every two weeks is required to keep it in good condition. If you stop hearing it, find out why.
- Clear yellow lights promptly. Deal with a warning while the generator still runs.
- Keep up the oil. Generac calls for an oil and filter change every 200 hours or two years, or every 100 hours in heat above 85°F. See the maintenance guide.
- Replace an old battery in spring. At three to five years old, it is cheap insurance.
If your generator needs work, request a service visit or call (352) 780-1430. You give your name, phone and address, and a licensed local technician who services generators will contact you. The request is free and there is no obligation. If you are weighing a replacement instead, the cost guide shows what a new unit runs.
Straight answers
Free in-home estimate, written price, no obligation.
Get my estimateWhy is there a red light on my generator?
On Generac home standby units, a solid red light means the generator is OFF, and a flashing red light means a fault was detected. Generac says service from a dealer may be required. Note the code on the screen or in the Mobile Link app first. If the code returns after you clear it, Generac says the unit needs service.
My generator will not start. What should I check first?
Make sure the controller is in AUTO, the fuel shutoff valve is on, and a propane tank is not empty. Look for a code on the screen. If the starting battery is three to five years old, it is a likely suspect. Do not open the engine compartment, since a standby unit can start by itself. If those checks do not fix it, request a service visit.
How much does generator repair cost around Ocala?
Yelp's 2026 cost guide puts most repairs on permanent whole-house units at about $150 to $600. Another national guide lists a $75 to $150 trip charge for on-site diagnosis. Major parts such as a stator or a transfer switch can cost more. These are published ranges, not a quote. Your exact price comes from the technician after diagnosis.
Should I call the brand's dealer or a local technician?
If the generator is under warranty, start with the brand. Generac and Champion both say warranty repairs go through their own dealer networks, and Generac requires proof of scheduled maintenance. Once the warranty is over, or if the brand's dealer cannot reach you, a request through this site matches you with a licensed local technician who services generators.
Do you repair Generac, Kohler and other brands?
Ocala Generators is a referral service and does not repair equipment itself. One request matches you with an independent, licensed local technician who services generators. Many technicians work on several brands, including Generac, Kohler (now Rehlko), Briggs & Stratton, Cummins and Champion. Ask about your brand when the technician calls.
I smell gas near my generator. What do I do?
Leave the house right away and do not try to find the leak or restart the generator. TECO Peoples Gas says to leave the area, call 911, then call its 24 hour line at 877-832-6747. On propane, call 911 and then your propane supplier. Have a technician look at the generator only after the gas company says it is safe.